1 | Protection class IP 54 |
2 | Protection class IP 67 |
E | No wireless data transmission |
l6 In meters (cable length) | l1 | l2 | l3 | l4 | l5 | h1 | h2 | h3 | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0,2 | 0,3 | 0,5 | 0,8 | 1,2 | 2 | 2,5 | 72 | 12 | 28 | 21 | 7 | 37 | 20,5 | 16,5 |
Tension feed |
Lithium battery 1/2 AA 3,6 V |
||||||||||
Battery life |
3 years |
||||||||||
Display |
7-digit LCD display, |
||||||||||
Reading scale |
-199999; 999999 |
||||||||||
Number of decimal digits |
programmable |
||||||||||
Units of measure |
mm, inch or degrees |
||||||||||
Max operating speed |
1 - 5 m/s programmable (reading speed affects battery life) |
||||||||||
Resolution |
0.01 mm / 0.001 in / 0,01° |
||||||||||
Precision |
± 0.03 mm |
||||||||||
Repeatability |
0.0002 x L mm (L = value measured in mm) |
||||||||||
Self-diagnostic |
Battery check, sensor check, magnetic tape check |
||||||||||
Reverse voltage protection |
Yes |
||||||||||
Temperature range |
0 °C ... 50 °C |
||||||||||
Operating environment |
Internal use |
||||||||||
Relative humidity |
Max. 95% at 25°C (without condensation) |
One advantage of using an electronic positioning device lies in the wide range of display options of the magnetic measuring system.
The lithium battery has a lifespan of over 3 years. A display symbol indicates when the battery needs to be replaced. The battery can be easily replaced by removing the rear cover. If the battery is replaced within 5 seconds, the buffer power supply prevents the loss of the configured parameters. |
|
||||||||||||||||||||
Show / Hide columns
|
|
|||||||||||
To ensure an accurate measurement, the distance between the sensor and the magnetic band should not exceed 1 mm. The sensor can be mounted using M3 screws. |
|||||||||||
Our service team is available from Monday to Friday between 7:00 AM and 5:30 PM: +49 7723 6507 - 0