A | Connector plug at the top |
B | Connector plug from the bottom |
C | Connector plug at the back (with 0,2 m cable) |
l1 | l2 | l3 | l4 | l5 | h1 | h2 | m1 | m2 | m3 | m4 |
---|---|---|---|---|---|---|---|---|---|---|
76 | 126 | 40 | 99,4 | 22 | 15,5 | 31,5 | 88 | 29 | 41 | 9 |
Maximal load Information with safety factor |
|
||||||||||
Examples of calculation |
F max. |
2000 N |
2000 N |
2000 N |
|||||||
Fixing |
from the back, 10 x threads M6, 8 mm deep |
||||||||||
Recommended torque |
10 Nm (Screws M6) |
||||||||||
Protection type |
IP67 / IP69K |
acc. to EN 60529 |
|||||||||
Switching principle, contact opening |
Slow-action contacts |
acc. to IEC 60947-5-1 |
|||||||||
Contact material |
Silver alloy |
||||||||||
Operating travel diagram |
The switching points are adjustable up to 2° in direction of 0°. |
||||||||||
Maximum operating frequency |
600 operating cycles / hour |
acc. to IEC 60947-5-1 |
|||||||||
Mechanical life span |
106 operating cycles |
||||||||||
Actuating speed |
min. 2° / second, max. 90° / second |
Utilization category |
AC 15: 24 Vac / 2A / DC 13: 24 Vdc / 2A (connector plug) |
acc. to EN 60947-5-1 |
|||||||||
Contacts, termination |
|||||||||||
Type of cable |
9x0,34 mm², PVC H05VV-F, black |
acc. to IEC 60332-1 |
|||||||||
Short-circuit current |
1000 A |
acc. to EN 60947-5-1 |
|||||||||
Rated insulation voltage |
30 V AC / 36 V DC (connector plug) / 250 Vac (cable) |
||||||||||
Short-circuit protection |
2 A, 500 V, Typ gG (connector plug) / 3 A, 500 V, Typ gG (cable) |
||||||||||
Ambient temperature |
|
||||||||||
Degree of pollution, external |
3 |
acc. to EN 60947-5-1 |
|||||||||
Safety parameters |
B10: 1 000 000, B10 d: 5 000 000, |
acc. to EN ISO 13849-1 |
Low-voltage switchgear and controlgear |
EN 60947-1/2007 |
||||||||||
Safety applications |
until SIL 3 / PL e |
acc. to EN ISO 13849-1 |
|||||||||
Other important details and hints are given in the operating instruction for GN 139.5 hinges which are included with every hinge and which are also available as PDF downloads from Operating instructions. The hinges with safety switch must be mounted and commissioned by qualified technical personnel in compliance with the details given in the operating instructions and with the national and international rules and regulations and the applicable standards. Otto Ganter GmbH & Co. KG will assume no statutory liability for missing or incorrect information and for any |
Our service team is available from Monday to Friday between 7:00 AM and 5:30 PM: +49 7723 6507 - 0